OpEraTiON
Operation
4.1.1 User interface
Button
Designation
Description
"Fan" button
Switching fan enabling on and off
"OK" button
Selection;
Confirm settings
"Menu" button
Call up and exit menu
"+" button
Call up menu items;
Change settings
"–" button
Call up menu items;
Change settings
4.1.2 Display
If no user action occurs for 30 seconds, the backlighting switches
off. Press any button to switch the background lighting on again.
Symbols
Note
If heat transfer (discharge) is controlled via a wall mount-
ed room temperature controller, not all symbols will be
displayed.
Symbol
Description
Time display:
Indication of the current time or a programmed start time
Timer mode:
The appliance heats in accordance with the enabled time pro-
gram.
Comfort mode:
The appliance maintains the set comfort temperature.
Standard setting: 21.0 °C. Use this setting for comfortable room
temperatures when someone is present.
Setback mode:
The appliance maintains the selected setback temperature.
Standard setting: 18.0 °C. Use this setting e.g. at night or when
absent for several hours.
Adaptive start:
In timer mode, the heating appliance switching times are adjust-
ed to ensure that, at the programmed start time, the respective
set room temperature is already reached.
Conditions: The "Adaptive start" function is enabled (see chapter
"Settings with integral room temperature controller / Standard
menu").
Window open detection:
To avoid unnecessary energy consumption while ventilating the
room, the appliance automatically reduces the set room temper-
ature to 7.0 °C for one hour if a window is open. The "Window
open detection" symbol flashes. After ventilation, window open
detection can be terminated manually by pressing "+" or "OK". The
appliance then heats to the set room temperature again.
Conditions: Window open detection is enabled (see chapter
"Settings with integral room temperature controller / Standard
menu").
Operating lock:
To lock or unlock the user interface, press and hold "+" and "–"
simultaneously for 5 seconds.
Enable the booster heater (accessory):
If storage heating is insufficient to heat a room, the booster heat-
er will provide additional heat.
Room temperature display
6
| SHF | SHS | SHL
Symbol
Description
Fan enabled:
If the room temperature falls below the set room temperature, the
fan switches on and delivers heated air to the room until the set
temperature has been reached.
Editable parameter:
The parameter shown can be changed using "+" and "–".
Days of the week:
1 = Monday, 2 = Tuesday ... 7 = Sunday
4.2
Heat storage
The degree of heat storage (charge) is set via the charge controller.
The settings you have to make via the charge controller depend
on whether you use an appliance with or without a central weath-
er-compensated charge control system.
The weather-compensated charge control system is located in
the control panel.
4.2.1 Appliances with a weather-compensated charge control
system
f Press the "Menu" button to open the charge level reducer in
the standard menu (see chapter "Settings with integral room
temperature controller / Standard menu").
f Press "OK". Once the "Editable parameter" symbol appears,
set the charge level reducer to 100 % with the "+" and "–"
buttons.
Note
If heat transfer (discharge) is controlled by a wall mount-
ed room temperature controller, adjust the charge level
reducer on the standard display with the "+" and "–" but-
tons.
The weather-compensated charge control system ensures the
correct charge level.
Note
Observe the instructions of the charge control system or
group control unit.
For separate control of individual appliances, you can also manu-
ally adjust the charge volume via the charge level reducer.
If you set the charge level reducer to 0 %, no charging takes place.
4.2.2 Appliances without a weather-compensated charge
control system
You have the following two options for charging without weath-
er-compensated charge control:
Charge control via the charge level reducer
The charge volume is set by means of the charge level reducer.
f Press the "Menu" button to open the charge level reducer in
the standard menu (see chapter "Settings with integral room
temperature controller / Standard menu").
f Press "OK". Once the "Editable parameter" symbol appears,
adjust the charge level reducer with the "+" and "–" buttons.