OpEraTiON
Settings with wall mounted room temperature controller
5.3.4 Contractor access
Display
Description
CodE
Contractor access
Note
Some menu items are protected by a code and can only
be accessed and adjusted by a qualified contractor.
6.
Settings with wall mounted room
temperature controller
Note
If heat transfer (discharge) is controlled via a wall mount-
ed room temperature controller, only a very limited num-
ber of adjustment options are available to you on the
appliance.
6.1
Standard display
The standard display is continuously displayed. If no user action
is performed for longer than 30 seconds while in the menu, the
device automatically switches to the standard display.
The standard display shows the current setting of the charge level
reducer as well as the "Editable parameter" symbol. For days
when the heat demand is lower, you can adjust the charge volume
manually in 10 % increments using the "+" and "–" buttons.
6.2
Standard menu
Note
You can call up the standard menu only if your appliance
is fitted with a booster heater (accessory).
To access the standard menu, briefly press "Menu".
Display
Description
Switch booster heater (accessory) on or off
Even if the wall mounted room temperature controller has a
booster heater switch, the booster heater must be switched
on in the standard menu.
If you wish to change the setting of the menu item, press the "OK"
button.
As soon as the "Editable parameter" symbol appears, you can
change the setting of the menu item with "+" and "–". Press "OK"
to save the setting.
To exit the standard menu, press "Menu". The standard display
appears.
10
| SHF | SHS | SHL
6.3
Configuration menu
Display
Description
I2
Actual value
P5
Parameters
CodE
Contractor access
To access the configuration menu, press and hold "Menu". After
approx. 3 seconds, actual value I2 is displayed.
Use "+" and "–" to switch between the individual actual value and
the parameter.
To exit the configuration menu, press "Menu". The standard dis-
play appears.
6.3.1 Actual value
Display
Description
I2
Relative heating time
(The counter can be reset via parameter P5.)
Note
The counter for relative heating time  (I2) counts the
charge time in complete hours run. The counter increas-
es when the appliance has been charged for a full hour,
even if this is split between shorter periods.
6.3.2 Parameters
Display
Description
P5
Reset relative heating time
Activating the parameter resets the counter for the
relative heating time (I2).
If you wish to change the setting of the parameter, press the "OK"
button.
As soon as the "Editable parameter" symbol appears, you can
adjust the setting of the parameter with the "+" and "–" buttons.
Press "OK" to save the setting.
6.3.3 Contractor access
Display
Description
CodE
Contractor access
Note
Some menu items are protected by a code and can only
be accessed and adjusted by a qualified contractor.
7.
Cleaning, care and maintenance
Material losses
!
- Never spray cleaning spray into the air slot.
- Ensure that no moisture can enter the appliance.
- If a pale brownish discolouration appears on the appliance
casing, wipe it off with a damp cloth.
- Clean the appliance when cold with ordinary cleaning prod-
ucts. Avoid abrasive or corrosive cleaning products.
Unit
[h]
Options
on | off
www.stiebel-eltron.com