iNSTaLLaTiON
installation
12.5.1 Installation with floor brackets
The Vario T-support (accessory) allows the appliance to be in-
stalled with ground clearance.
If the appliance can be mounted on a wall with sufficient load
bearing capacity, the support only needs to be secured below the
appliance feet.
If no suitable mounting wall is available, secure the support to the
floor and the appliance feet.
12.6 SHS installation versions
1
1 Installation with wall mounting bracket on sufficiently load
bearing wall (SHS 1200-3600)
2 Installation with insufficiently load bearing wall with support
bracket
12.6.1 Securing the appliance with ground clearance using
wall mounting brackets
With this type of installation, observe the following:
If a sufficiently load bearing wall is available, the appliance can
be fixed to the installation wall using the wall mounting brackets
provided. For this, the following applies:
- SHS 1200-3600: The wall mounting bracket can bear the
weight of the appliance.
- SHS 4200-4800: The wall mounting bracket must be support-
ed with an additional support bracket (accessory).
- For a wall with a limited load bearing capacity, an additional
support bracket is also required for the SHS 1200-3600 appli-
ances (accessory).
16
| SHF | SHS | SHL
2
f Unscrew the two wall mounting brackets from the appliance
back panel.
f Secure the wall mounting brackets to the fixing wall, tak-
ing the minimum clearances and the dimensions for the
hole clearances into account. (For dimensions, see chapters
"Minimum clearances" and "Specification / Dimensions and
connections").
f Hook the appliance into the wall mounting brackets.
12.7 Inserting storage blocks
WARNING Burns
Broken insulation can lead to the casing overheating.
f Check the thermal insulation in the appliance for transport
damage.
f Replace faulty thermal insulation.
The appliance must be completely free of foreign bodies such as
parts of the packaging.
f Remove the cover panel and cardboard inserts from the inte-
rior of the appliance.
The storage blocks are delivered in separate packaging. Storage
blocks with slight transport damage can be used. This does not
impair the function of the appliance.
1
2
1 Heating element
2 Storage block
f To insert the storage blocks, raise the heating elements
slightly.