Télécharger Imprimer la page

Güde GZM 120 Traduction Du Manuel D'utilisation D'origine page 23

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
Disposal
Waste batteries and waste electrical
and electronic equipment must not be
disposed of together with household
waste. Waste batteries and waste elec-
trical and electronic equipment must be
collected and disposed of separately. Re-
move used batteries, accumulators and
lamps from the devices before disposing
of them. Ask the local authorities or
your retailer about recycling centres and
collection points. Depending on local
regulations, retailers may be obliged to
take back used batteries and waste elec-
trical and electronic equipment free of
charge. Help reduce the demand for raw
materials by reusing and recycling your
used batteries and waste electrical and
electronic equipment. Waste batteries
(especially lithium-ion batteries) and wa-
ste electrical and electronic equipment
contain valuable, recyclable materials
that can have a negative impact on the
environment and your health if not dis-
posed of in an environmentally friendly
manner. Delete any personal data on
your old device before disposing of it.
Failure removal
Failures  
Engine does not start
Engine growling, running but not
starting
Equipment starting but getting
blocked under small load and
switching automatically off
The contact pressure of the hand
wheel is too loose
Drum not rotating after starting the
machine
Causes
No power supply.
Broken cable
Defective condenser
The extension cable is too long or
with a small cross section
The socket is too far from the main
line and the extension cable has a
small cross section
The pressure spring is not sufficiently
tight
Defective V-belt or mismatching
voltage
Removal
Check the voltage. Technical data
given on the type label must corre-
spond with electric network voltage.
Any checks or replacements to be
provided by a professional electrician
Deliver the machine to the customer
service centre for repair
Extension cable to be at least 1.5
mm2 for a length of up to 25 m
Cross section of at least 2.5 mm2 for
longer cables
Tighten the screw on the pressure
spring
V-belt replacement