PAIRED OPERATION
Two connected operators are controlled with one command.
Electrical connections
Connect the two electronic boards with a UTP CAT 5 cable.
Insert an RSE card into both control boards.
Connect up the electrics for the devices and accessories.
The devices and accessories must be connected to the control board which will be set as the MASTER.
For information on connecting the electrics for the devices and accessories, please see the "ELECTRICAL CONNECTIONS" section.
Programming
All programming operations described below must be performed only on the control board set as the MASTER.
F49 RSE communication
F54 Opening direction
F52 Transferring MASTER-SLAVE parameters
A3
Travel calibration
Saving users
All save user operations must be performed only on the control board set as the MASTER.
Operating modes
1
PARTIAL OPENING command
2
STEP-BY-STEP or OPEN ONLY command
1
2
UTP CAT5 (max 1000m)
A B GND
RSE
MASTER
MASTER
A B GND
RSE
SLAVE
SLAVE