Safety devices test
Check that the photocells connected to the selected inputs are operating correctly, after each opening and closing command.
Run the test by connecting the photocells to the TS terminal [see paragraph on Safety devices].
F5
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
F6
Command 2-7
Associate a command to the connected device on 2-7.
F7
Command 2-3P
Associate a command to the connected device on 2-3P.
F8
Obstacle with motor stopped
With the function active, the gate remains idle if the safety devices detect an obstacle. The function is active when the gate is closed, open or after a complete stop.
F9
Encoder
Manage operator slowdowns, obstacle detection and sensitivity.
F11
Sensor type
Choose the type of access device.
F14
OFF (Default)
1 = CX
2 = CY
4 = CX+CY
OFF (Default)
ON
0 = Step-by-step (default) - The first command is to open and the second to close.
1 = Sequential - The first command is to open, the second to STOP, the third to close and the fourth to STOP.
2 = Open
3 = Close
1 = Partial opening (Default)
The partial opening time is set from the function [F71 - Partial opening time].
The degree of partial opening is set as a percentage using the [F36 – Adjusting the partial opening] function.
2 = Open
OFF (Default)
ON
OFF
ON (Default)
0 = Transponder selector switch
1 = Keypad selector (default)