Additional light
Choose the operating mode for the lighting device connected to output E1.
F18
Automatic closure
Set the time before automatic closure, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
F19
Automatic closing after partial opening
Set the time before automatic closure after a partial opening command.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
Do not deactivate the function [F19 - Automatic close].
F20
Pre-flashing time
Adjust the time for which the beacon is activated before each manoeuvre.
F21
Opening slowdown speed
Set the slowdown speed during opening (as a percentage of the maximum speed).
This function appears only if the [F11 - Encoder] function is active.
F30
Travel sensitivity
Adjust the obstruction detection sensitivity during the gate travel in percentage terms.
This function appears only if the [F11 - Encoder] function is active.
F34
0 =Flashing beacon (Default)
1 = Cycle light - The lamp stays on during the manoeuvre.
The light remains off if an automatic closing time is not set.
This parameter does not appear if the [F19 - Automatic Close] function is deactivated.
OFF (Default)
From 1 to 180 seconds
OFF
1 to 180 seconds (Default 10)
OFF (Default)
1 to 10 seconds
OFF
1 = High (Default)
2 = Medium
3 = Low
10% to 100% (Default 100%)
10% = minimum thrust and high obstruction sensitivity
100 % =maximum thrust and low obstruction sensitivity