New user
Register up to a maximum of 250 users and assign a function to each one.
The operation can be carried out by using a transmitter or another control device. The boards that manage the control devices (AF - R700 - R800) must
be inserted into the connectors.
U1
Remove user
Remove one of the registered users.
U2
Remove all
Remove all registered users.
U3
Radio decoding
Choose the type of radio coding for the transmitters enabled to control the operator.
If you choose the type of radio coding for the transmitters [Rolling code] or [TW key block], any transmitters with a different type of radio coding saved
previously will be deleted.
U4
Motor type
Set the type of gearmotor installed.
A1
Travel calibration
Start the travel self-learning.
This function appears only if the [F11 - Encoder] function is active.
A3
1 = Step-by-step - The first command is to open and the second to close.
2 = Sequential - The first command is to open, the second to STOP, the third to close and the fourth to STOP.
3 = Open
4 = Partial opening
Choose the function to be assigned to the user.
Press ENTER to confirm.
The free position in the memory is shown intermittently for a maximum of 10 seconds. During this phase, send the code
from the control device.
Repeat the procedure to add other users.
Use the arrows to choose the number associated with the user you want to remove.
Alternatively, the control device associated with the user you want to remove can be activated.
Press ENTER to confirm.
"CLr" will appear to confirm deletion.
No. 1 > 250
OFF (Default)
ON (Run operation)
1 = All decoding (default)
2 = Rolling code
3 = TW key block
1 = BX704
2 = BX708
OFF (Default)
ON (Run operation)