Determining the travel end points with mechanical limit switches
1
Open the gate.
2
Insert the opening limit-switch tab in the rack.
The spring must trigger the microswitch.
3
Fasten the opening limit-switch tab using the grub screws supplied.
~ 20 mm
4
Close the gate.
5
Insert the closing limit-switch tab in the rack.
The spring must trigger the microswitch.
6
Fasten the closing limit-switch tab using the grub screws supplied.
2 2
1
2
1
~ 20 mm