Transferring MASTER-SLAVE parameters
Share the parameters programmed on the master gate with the slave gate.
This function appears only if the [F49 - RSE] function is active.
F52
Opening direction
Set the gate opening direction.
F54
CRP address
Assign a unique identification code (CRP address) to the control board.
The function is used where there are multiple operators connected to the same communication BUS using the CRP protocol.
F56
RSE speed
Set the remote connection system communication speed on the RSE port.
F63
RIO ED T1 and RIO ED T2
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
F65
F66
RIO PH T1 and RIO PH T2
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
F67
F68
Partial opening time
Adjust the gate opening time.
F71
OFF (Default)
ON
0 = To the left (default)
1 = To the right
from 1 to 255
0 = 1200 bps
1 = 2400 bps
2 = 4800 bps
3 = 9600 bps
4 = 14400 bps
5 = 19200 bps
6 = 38400 bps (default)
7 = 57600 bps
8 = 115200 bps
OFF (Default)
P0 = It stops the gate and excludes automatic closing. Use a control device to resume movement.
P7 = Reopen while closing.
P8 = Reclose while opening.
OFF (Default)
P1 = Reopen while closing.
P2 = Reclose while opening.
P3 = Partial stop.
P4 = Obstacle standby.
5 to 40 seconds (Default 5)