ELECTRICAL CONNECTIONS
Passing the electrical cables
Connect all wires and cables in compliance with the law.
The electrical cables must not touch any parts that may overheat during use (such as the motor and transformer).
Use cable glands to connect the devices to the control panel. One of these must be used exclusively for the power supply cable.
1
Cable glands on the board holder
Power supply
Make sure the mains power supply is disconnected during all installation procedures.
Before working on the control panel, disconnect the mains power supply and remove the batteries, if any.
Connecting to the mains (230/120 V AC - 50/60 Hz)
120 / 230 V AC
50/60 Hz
Maximum capacity of contacts
Device
Additional light
Flashing beacon
Operator status warning light
Output
Power supply (V)
W - E1
W - E1
11 - FC / 11 - FA
Power (W)
230 AC
60
230 AC
25
24 AC
3