Command and control devices
1
Keypad selector
Card reader
2
Transponder selector switch
3
4
STOP button (NC contact)
Stop the gate and exclude automatic closing. Use a control device to resume movement.
If the contact is not used, it must be deactivated during programming.
Control device (NO contact)
5
PARTIAL OPENING function
6
Control device (NO contact)
OPEN-CLOSE (step-by-step) or OPEN-STOP-CLOSE-STOP (sequential) function
7
Antenna with RG58 cable
1
2
Safety devices
During programming, configure the type of action that must be performed by the device connected to the input.
Connect the safety devices to the CX and/or CY inputs.
If contacts CX and/or CY are not used, they must be deactivated during programming.
DELTA photocells
Standard connection
+
-
10
11 NO C NC
RX
A B
S1GND
4
3
+
-
10
11
TX
5
6
DELTA photocells
Connection with safety test
See function [F5] Safety devices test.
+
-
10
11 NO C NC
RX
7
+
-
10
11
TX