Table VIII: Electrical data (Cooling only models)
kW
4,2
(4)
5,3
(4)
7,2
(4)
8,0
(4)
(4)
4,2
(4)
5,3
(4)
7,2
10,5
(4)
14,0
(4)
17,6
(4)
(4)
2 x 2,8
(4)
2 x 3,5
(3-4)
2 x 5,3
(3-4)
2 x 7,2
(3-4)
2 x 3,5
(3-4)
3 x 5,3
NOTES: 1. Speed up time is usually less than 1 second. 2. In standard applications with lengths up to 15 m, the above mentioned wire sizes assure a voltage drop not exceeding 3%. For special applications
(e.g. wires exposed to the sun in tropical zones) or for wire lengths exceeding the values shown, it is necessary to check the percent voltage drop and if necessary choose the next larger size.
In sizing the wires, you must consider the current drawn under maximum conditions, when air conditioners are installed (46 or 52 °C d.b., 32 °C w.b.) 3. Electrical data refer to single circuit units.
4. The electric heater of the indoor unit has an independent power supply. 5. The indoor unit cabinet type models with capacities 4.2 - 5.3 - 7.2 kW in heat pump version, include the electric
heater; therefore to values in table add 7.5 A - 1800W
Tabella VIII: Caratteristiche elettriche (modelli solo raffrescamento)
Corrente
kW
4,2
(4)
5,3
(4)
7,2
(4)
8,0
(4)
4,2
(4)
5,3
(4)
7,2
(4)
10,5
(4)
14,0
(4)
17,6
(4)
2 x 2,8
(4)
2 x 3,5
(4)
2 x 5,3
(3-4)
2 x 7,2
(3-4)
(3-4)
2 x 3,5
(3-4)
3 x 5,3
NOTE: 1.La durata dello spunto è normalmente inferiore a 1 secondo. - 2. La sezione dei conduttori sopra indicata, in applicazioni normali con linee fino a 15 m circa, assicura cadute di tensione non superiori
al 3%. In casi di applicazioni particolari (ad esempio cavi esposti al sole in zone tropicali) o linee di lunghezza eccessiva è necessario controllare la caduta di tensione ed eventualmente passare alla sezione
di cavo direttamente superiore. Nel dimensionare i cavi, considerare gli assorbimenti in Ampères nelle condizioni di punta con le temperature massime che possono verificarsi nelle località dove i climatizzatori
sono installati (46 o 52 ° C b.s., 32 ° C b.u.). 3. Dati elettrici riferiti al singolo circuito. 4. Il riscaldatore elettrico dell'unità interna ha linea di alimentazione separata. 5. Le unità interne tipo a mobiletto
modelli da 4.2 - 5.3 - 7.2 kW a pompa di calore, includono il riscaldatore elettrico; ai valori in tabella aggiungere 7.5 A - 1800W
Operating electric draws - cooling
Locked
Nominal conditions for
Nominal conditions for
rotor
TEMPERATE CLIMATE
TROPICAL CLIMATE
current
ISO R 859 Type A
ISO R 859 Type B
ind. 27 °C d.b., 19 °C w.b.
ind. 29 °C d.b., 19 °C w.b.
(1)
out. 35 °C d.b., 24 °C w.b.
out. 46 °C d.b., 24 °C w.b.
A
A
W
A
34
5,8
1320
7,4
49
8,6
1820
9,8
64
13,4
2900
15,9
80
17,0
2950
19,5
22
3,9
1850
4,3
24
4,1
2200
4,7
30
6,2
3280
7,0
33
7,4
3670
8,3
56
9,7
4960
10,6
65
12,9
6070
14,3
2x30 11,5
2380
13,1
2x28 10,3
2350
12,4
49
8,6
1870
9,9
64
14,0
2920
15,8
37
4,9
1120
6,2
49
8,9
1900
10,1
Assorbimenti elettrici di esercizio in raffrescamento
Condizioni nominali per
Condizioni nominali per
di
CLIMI TEMPERATI
CLIMI TROPICALI
spunto
ISO R 859 Tipo A
ISO R 859 Tipo B
int. 27 ° C b.s., 19 ° C b.u.
int. 29 ° C b.s., 19 ° C b.u.
(1)
est. 35 ° C b.s., 24 ° C b.u.
est. 46 ° C b.s., 24 ° C b.u.
A
A
W
A
34
5,8
1320
7,4
49
8,6
1820
9,8
64
13,4
2900
15,9
80
17,0
2950
19,5
22
3,9
1850
4,3
24
4,1
2200
4,7
30
6,2
3280
7,0
33
7,4
3670
8,3
56
9,7
4960
10,6
65
12,9
6070
14,3
2x30 11,5
2380
13,1
2x28 10,3
2350
12,4
49
8,6
1870
9,9
64
14,0
2920
15,8
37
4,9
1120
6,2
49
8,9
1900
10,1
Max. condition
TROPICAL CLIMATE
ind. 32 °C d.b., 23 °C w.b.
ind. 32 °C d.b., 23 °C w.b.
out. 46 °C d.b., 32 °C w.b.
out. 52 °C d.b., 32 °C w.b.
W
A
W
1630
9,2
1770
2070
12,1
2260
3450
---
---
19,8
3370
---
---
22,7
2090
---
---
4,7
2530
---
---
6,3
3770
---
---
9,1
4100
---
---
10,5
5450
---
---
12,7
6940
---
---
17,0
2715
---
---
16,2
2650
16,4
3240
1940
12,2
2320
3300
---
---
19,8
1320
7,8
1560
1970
12,4
2350
Condizioni di punta in
CLIMI TROPICALI
int. 32 ° C b.s., 23 ° C b.u.
int. 32 ° C b.s., 23 ° C b.u.
est. 46 ° C b.s., 32 ° C b.u.
est. 52 ° C b.s., 32 ° C b.u
W
A
W
1630
9,2
1770
2070 12,1
2260
3450
---
---
19,8
3370
---
---
22,7
2090
---
---
4,7
2530
---
---
6,3
3770
---
---
9,1
4100
---
---
10,5
5450
---
---
12,7
6940
---
---
17,0
2715
---
---
16,2
2650 16,4
3240
1940 12,2
2320
3300
---
---
19,8
1320
7,8
1560
1970 12,4
2350
30
Mains supply
Max. condition
TROPICAL CLIMATE
Delayed
Wire
fuses
size (2)
A
W
A
mm
---
---
16
4
---
---
16
4
3900
25
2 x 4
3660
25
2 x 4
2460
10
1,5
3130
10
1,5
4100
10
2,5
4600
16
2,5
6200
16
4
7600
25
6
2950
25
6
---
---
25
4
---
---
16
4
3620
25
6
---
---
12
4
---
---
16
4
Alim. di potenza
Condizioni di punta in
CLIMI TROPICALI
Fusibile
Sezione
Ritardato
Cavi (2)
A
W
A
mm
---
---
16
4
---
---
16
4
3900
25
2 x 4
3660
25
2 x 4
2460
10
1,5
3130
10
1,5
4100
10
2,5
4600
16
2,5
6200
16
4
7600
25
6
2950
25
6
---
---
25
4
---
---
16
4
3620
25
6
---
---
12
4
---
---
16
4
Auxiliaries
Delayed
Wire
fuses
size (2))
2
2
A
mm
4
1,5
4
1,5
4
1,5
4
1,5
Ausiliari
Fusibile
Sezione
Ritardato
Cavi (2)
2
2
A
mm
4
1,5
4
1,5
4
1,5
4
1,5