Table 4: C/Q timeout on connection loss
ISDU/index
Sub-index
Setting in
mSec
0x62
0x00
500 ... 65534
(default: 500)
65535
7.1.4 Configuring the product
1. Switch on the power supply.
ð Product obtains parameters and configuration from the IO-Link master.
ð The UL/UA and COMM LEDs illuminate green.
2. Connect pneumatic supply pressure.
3. Send payload data to IO-Link interface connection.
ð The respective valve LEDs are switched on as soon as the IO-Link master
has validated the data.
4. Switch on pneumatic supply pressure.
7.1.5 Defining bits
Table 5: Address table for PLC configuration
Valve position
Coil 14
1
Output 1 (X.0)
2
Output 3 (X.2)
3
Output 5 (X.4)
4
Output 7 (X.6)
5
Output 9 (X+1.0)
6
Output 11 (X+1.2)
7
Output 13 (X+1.4)
8
Output 15 (X+1.6)
9
Output 17 (X+2.0)
10
Output 19 (X+2.2)
11
Output 21 (X+2.4)
12
Output 23 (X+2.6)
13
Output 25 (X+3.0)
14
Output 27 (X+3.2)
15
Output 29 (X+3.4)
16
Output 31 (X+3.6)
17
Output 33 (X+4.0)
18
Output 35 (X+4.2)
19
Output 37 (X+4.4)
20
Output 39 (X+4.6)
21
Output 41 (X+5.0)
22
Output 43 (X+5.2)
23
Output 45 (X+5.4)
24
Output 47 (X+5.6)
The exact assignment of the solenoid coils to the output bits depends on the type
of valves used.
8 Operation
The device is operated through the system. Observe the information in the sys-
tem documentation.
8.1 Basic requirements
General requirements
• Never switch off, modify or bypass safety devices.
• Do not make any changes to the configuration and hardware during opera-
tion.
• Do not touch the product or any connected parts during operation.
In case of malfunctions during operation
• In case of a malfunction that presents an immediate danger for employees or
systems: Switch off product.
AVENTICS™ XVES | 570096-BAL-001-AA | English
Action on timeout
Valves are switched off.
Action on valves is stopped.
Coil 12
Output 2 (X.1)
Output 4 (X.3)
Output 6 (X.5)
Output 8 (X.7)
Output 10 (X+1.1)
Output 12 (X+1.3)
Output 14 (X+1.5)
Output 16 (X+1.7)
Output 18 (X+2.1)
Output 20 (X+2.3)
Output 22 (X+2.5)
Output 24 (X+2.7)
Output 26 (X+3.1)
Output 28 (X+3.3)
Output 30 (X+3.5)
Output 32 (X+3.7)
Output 34 (X+4.1)
Output 36 (X+4.3)
Output 38 (X+4.5)
Output 40 (X+4.7)
Output 42 (X+5.1)
Output 44 (X+5.3)
Output 46 (X+5.5)
Output 48 (X+5.7)
9 Service
9.1 Inspection
9.1.1 General requirements
Use in normal ambient conditions
Use in aggressive ambient conditions
Aggressive ambient conditions include, for example:
• Minimum or maximum permissible temperature. See
• Heavy accumulation of dirt
• Proximity to grease-dissolving liquids or vapors
Aggressive ambient conditions lead to further requirements for inspection:
• Adapt the inspection interval for seals to the ambient conditions.
9.1.2 Preparation
Implement safety measures. See
u
9.1.3 Procedure
Visual inspection
Visually inspect for integrity.
u
Detailed inspection
• Identifications and warnings on the product: The system owner has to replace
labels or warnings that are difficult to read immediately.
• Check the compressed air connections.
• Check the lines.
• Check tubing.
• Check the seals.
• Check to make sure that all fittings are properly connected.
• Check the safety devices on the system.
• Check the product functions.
9.2 Cleaning
9.2.1 General requirements
Cleaning intervals
• The system owner specifies the cleaning intervals in line with the ambient
conditions at the operating site.
Aids
• Only clean the product with damp cloths.
• Only use water for cleaning and a mild detergent, if necessary.
NOTICE! Make sure that no water or water mist can enter the product via the
compressed air connections. Penetrating fluids destroy seals and cause dam-
age to the product.
9.2.2 Procedure
1. Close all openings with suitable safety devices so that no cleaning agent can
enter into the system.
2. Remove all dust deposits from the product and the adjacent system parts.
3. If necessary, remove other production-related deposits from the product and
the adjacent system parts.
9.3 Maintenance
9.4 After service
If no damage has been detected and the operator has not reported any malfunc-
tions, the product can be reconnected to the power supply and put back into op-
eration.
g 14. Technical
g 6.2.2 Implementing safety
measures.
data.