general information

To help ensure years of trouble-
free operation, please read the
following manual carefully.
Before Operation:
Read the following instructions
care ful ly.
Reasonable
and safe meth ods should be
practiced. Check local codes and
requirements before installation.
Attention: This manual contains
important information for the safe
use of this product. Read this
manual completely before using
this product and refer to it often
for continued safe product use.
DO
NOT
THROW
OR
LOSE
THIS
Keep it in a safe place so that you
may refer to it often.
WARning:
Before
these pumps and controls,
always disconnect the power
first. Do not smoke or use
spark-able electrical devices or
flames in a septic (gaseous) or
possible septic sump.
NOTICE All installations where a
sump pump is permanently-wired
to the source of electrical supply
(control device or junction box)
must be performed only by qualified
personnel using the appropriate
tools, skills, and knowledge of
electrical safety. Such a connection
would not be considered readily
removable if the plug were cut off
the pump's power cord. Questions
relating to this type of installation
should be directed to your local
code authority.
California Proposition 65 Warning
This
product
related
accessories
chemicals known to the State of
California to cause cancer, birth
defects or other reproductive harm.
2
Pump Warning
To reduce risk of electrical
shock:
Risk of Electrical Shock:
This
pump
investigated for use in swimming
care
pool areas.
1. This pump is supplied with
a grounding conductor and
ground ing-type
plug.
electrical shock, be certain
that it is connected only
to
a
grounding-type receptacle.
2. Septic tank is to be vented
AWAY
in
accordance
MANUAL.
plumbing codes.
3. Do not smoke or use spark-
able
handling
flame in a septic (gaseous) or
pos si ble septic sump.
4. A septic sump condition may
exist and if entry into sump is
necessary, then (1) provide
proper
per OSHA requirements and
(2) do not enter sump until
these precautions are strictly
adhered to.
5. Do not install pump in location
classified as hazardous per
N.E.C., ANSI/NFPA 70 - 2001.
Fail ure to heed above cau-
tions could result in injury or
death.
Pump
installation
and
These
contain
must be followed for satisfactory
performance of your pump. Before
installation, check your local
electrical and plumbing codes.
has
not
been
attachment
To
reduce
risk
properly
grounded,
with
local
electrical
devices
safety
precautions
important
instructions
1. Provide proper sump
Minimum Sump Diameter
W-A1
D-A1
V-A1
Approx. Turn-On Level
W-A1
D-A1
V-A1
Approx. Turn-Off Level
W-A1
of
D-A1
V-A1
2. Make sure float (automatic
models) hangs free. It should
not come into contact with
side or bottom of sump pit.
3. Make sure sump is free of
string, cloth, nails, gravel, etc.
before in stall ing pump.
or
4. Do not set pump directly on
the bottom of sump if it is
not solid. Raise the pump by
placing bricks or concrete
blocks un der neath it.
5. Use steel or plastic pipe for
all connecting lines be tween
pump and sewer outlet.
NOTICE Some city regulations
do not allow in stall ing a pump
with plastic pipe. Check local
reg u la tions.
6. A check valve should be
installed in dis charge pipe, at
least twelve inches above the
discharge outlet of the pump.
7. Connect to power source
using
3-prong
115/230 volt AC receptacle.
Do not remove ground pin
from elec tri cal plug. Do not
use an ex ten sion cord.
8. For
proper
operation make sure the pump
power cord is plugged into
the back of the "pig gy back" re-
cep tacle on the switch cord.
9. Use pump submerged for
pumping
waterlike
(temperature to 120° F).
18"
12"
12"
9-1/2"
10"
7-7/8"
3-1/2"
4"
3-3/8"
grounded
automatic
liquids