GENERAL INFORMATION

DESCRIPTION
Pentair Myers® submersible effluent pumps and submersible
sewage pumps support effluent, sewage and wastewater removal,as
well as sump drainage in residential sewage systems. In commercial
and industrial systems, these pumps support liquid transfer,
circulation, dewatering and flood control applications.
Drymotors are 60 Hz, 4/10 through 1 HP, 115 or 230 volt single phase.
Models deliver from 27 to 36 ft of head with maximum capacities
ranging from 92 to 145 GPM. Single phase models have built-in thermal
overload protection. Three-phase model requires external overload
protection.
Pumps are entirely constructed of stainless steel, including a
self-cleaning cast stainless steel impeller. The oil chamber provides
sealprotection.1-1⁄2"and2"solidshandlingcapability.Refertothe
Specifications section of this manual for details. The NBR 70 rubber lip
seal includes a special sand guard V-ring for better sand handling.
A 2' discharge elbow is also included with pump.
Pumps must be installed in a vertical position only. Installing
a pump in any other position will void the warranty. Not for use
with salt water or brine.
UNPACKING AND INSPECTION
Handle with care. Check items received against packing list to
be sure that all equipment arrived. Inspect for shipping damage.
If damage is found, file a claim with the carrier immediately.