General Information; Pump Installation - Pentair MSP40 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

General
Information
Thank
you
for
your Myers
pump. To help
®
ensure years of trouble-free
op er a tion,
please
fol low ing manual carefully.
Before Operation:
Read
the
following
tions care ful ly. Reasonable care
and safe meth ods should be
practiced. Check local codes and
requirements before installation.
Attention:
This manual contains important
information for the safe use of
this product.
Read this manual
completely before using this
product and refer to it often
for con tin ued safe product use.
DO NOT THROW AWAY OR
LOSE THIS MAN U AL.
it in a safe place so that you may
refer to it often.
WARNING: Before handling
these pumps and controls,
always disconnect the power
first. Do not smoke or use
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.
California
Proposition
Warning
This product and related
accessories
contain
known to the State of California to
cause cancer, birth defects or other
reproductive harm.
Pump
Warning
To reduce risk of electrical shock:
1. Risk of Electrical Shock:
This pump has not been
in ves ti gat ed
for
swimming pool areas.
2
2. Risk of Electrical Shock:
Connect only to a properly
ground ed receptacle.
Septic tank to be vented
in ac cor dance with local
purchasing
plumbing codes.
Do not smoke or use sparkable
electrical devices or flame in
read
the
a septic (gaseous) or possible
septic sump.
If a septic sump condition
in struc-
exists and if entry into sump is
necessary, then (1) provide
proper safety precautions per
OSHA re quire ments and (2)
do not enter sump until these
precautions
adhered to.
Do not install pump in location
clas si fied as hazardous per
N.E.C., ANSI/NFPA 70 - 2001.
Failure to heed above cautions
could result in injury or death.
Keep
Pump
Installation
These
must be followed for satisfactory
performance of your pump.
Before
your
65
plumbing codes.
1. Provide proper sump size
to
chemicals
operate without restrictions. A
two- to five-minute run time is
recommended. Also, minimum
24" diameter recommended.
2. Make sure sump is free of
string, cloth, nails, gravel, etc.
before installing pump.
3. Do not set pump directly on
the bottom of sump pit if it
is not solid. Raise the pump
by placing bricks or concrete
blocks underneath it.
use
in
are
strictly
important
instructions
installation,
check
local
electrical
allow
the
pump
4. Use steel or plastic pipe for all
connecting
pump and sewer outlet.
NOTE: Some city regulations
do not allow installing a pump
with plastic pipe. Check local
regulations.
5. In applications where the
pump may sit idle for months
at a time, it is recommended
that the pump(s) be cycled
every month to ensure the
pumping system is working
properly when needed.
6. A check valve should be
installed in discharge pipe, at
least 12" above the discharge
outlet of the pump.
7. An audible alarm system, such
as
the
SA-1,
water conditions should be
installed in every pump for
greater protection.
NOTE: Alarm is for indoor
use only. Contact your Myers
distributor for other panel
applications.
WARNING: When using
the automatic diaphragm
switch the vent tube in
and
the plug must be clear of
obstructions.
to
Do not bend cord. This will
cause a crimp in the vent tube
and switch failure will occur.
Pump should be plugged into
a single outlet, where vent
tube can "breathe." Blocking
tube or bending cord will void
the warranty.
8. Connect to power source
using
3-prong
AC
receptacle.
remove ground pin from
electrical plug. Do not use an
extension cord.
lines
between
for
high
grounded
Do
not