TECHNICAL DATA

7.1
TECHNICAL DATA
Model
Weight
Nominal power
Nominal power given to water
Nominal power given to environment
Efficiency
Emissions CO (13% O2)
Chimney vacuum
Exhaust gas temperature (*)
Exhaust gas flow
Boiler capacity
System pressure (max)
Combustible consumption
Max. combustible quantity
Autonomy
Electric power
Tension
Frequency
(*) Average temperature at nominal power. It is possible to obtain higher instantaneous exhaust gas temperatures. It is
recommended to use always pipes with minimum specify T400.
• Air the place • Open the starting key • Use
well dried wood • Burn specified product exi-
sting in commerce • Verify that no other com-
bustion based device is working in the same
room. • If necessary, open slightly the ash door
for the time necessary for a safe lighting.
• Do not clean the plate with water • Do the
regular maintenance of the plate as describe •
Contact your dealer or the customer service
RTE 60
RTE 80
RTVE 60
RTVE 80
193 kg
235 kg
18,6 kW
22,3 kW
8,5 kW
15,1 kW
10,1 kW
7,1 kW
79,0 %
75,7 %
0,87%
0,11%
12 Pa
12 Pa
259 °C
193 °C
11,7 g/s
36,8 g/s
15 liters
15 liters
3 bar
3 bar
4,7 kg/h
7 kg/h
6 kg
7 kg
1 h
1 h
-
25 W
-
230 V
-
50 Hz
138
RTE 90
RTVE 90
260 kg
22,3 kW
15,1 kW
7,1 kW
75,7 %
0,11%
12 Pa
193 °C
36,8 g/s
15 liters
3 bar
7 kg/h
7 kg
1 h
25 W
230 V
50 Hz