3
HEATING SYSTEM
3.1
GENERAL NOTES
RTE and RTVE thermal cookers are endowed with
boiler to use the heating produced by the device
through a system with fluid vector for heating
and for the production of hot water. The system
must be designed according to UNI 10412-2:2006
law by a qualified thermal technician and must be
installed by experienced people according to ex-
3.2
CONNECTIONS TO THE HEATING SYSTEM
RTE 60 - RTVE 60
with flue outlet on the right side
1) Connection detector of auxiliary thermostat
(optional) ø ½'' female
2) Going connection ø 1''¼ female
3) Bulb for thermal discharge detector
(optional) ø ½'' female
4) Connection for thermal discharge circuit
(optional) ø ½'' male
5) Return connection ø 1''¼ female
6) Connection discharge ø ½ female
Picture 19 - Hydraulic connection scheme of a thermal cooker RTE 60 and RTVE 60 with flue outlet on the
right side (rear sight). The thermal cooker with flue outlet on the left side is symmetrical.
isting laws in particular to UNI 10683:2005 law.
The thermal cookers are endowed with all the
necessary predispositions for a correct installa-
tion, every external component (as pumps, valves,
acoustic alarms, pressure switches) must be ob-
tained by third parts according to the specifies of
designer and installer.
6
5
4
2
600
6
5
4
3
117
800/900
3
1
4
747
684
634
256
127
92
2
1
4
747
684
634
256
127
42