The Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical shorts,
consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120 V, 60 Hz, 250 W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
DISCONNECT POWER
SUPPLY BEFORE SERVICE
OR MAINTENANCE.
FUEL INPUT
RATING:
GROUNDED
2.4 LB/H
POWER CORD
(1.1 KG/H)
BURN POT
INDEX
W : WHITE
Y : YELLOW
P : PURPLE
R : RED
K : BLACK
S : SILVER
20
ELECTRICAL WIRE DIAGRAM
REMOVE TWO GREASE
TRAY BRACKETS FROM
UNDERSIDE OF UNIT.
K
K
W
W
G
GROUND
W
P
W
W
W
W
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
120V, 200W
REMOVE WIRE COMPONENTS
HOUSING FROM UNDERSIDE
OF UNIT.
W
GRILL PROBE
CONNECTORS
FAST-BLOW FUSE
P
Y
P
Y
R
W
W
R R
AUGER MOTOR
& FEED SYSTEM
120V, 60Hz,
2 RPM MOTOR
ACCESS WIRING COMPONENTS
LOCATED IN TEMPERATURE
PROBE HOUSING.
GRILL
S
PROBE
CONTROL BOARD
Y
Y
Y
DRAFT FAN
120V, 60Hz,
1 PHASE