Télécharger Imprimer la page

BFT THALIA BT A80 Instructions D'installation page 55

Masquer les pouces Voir aussi pour THALIA BT A80:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
Logic
Definition
Configuration of
EXPI2 input
on input-output
2 EXPI
expansion board.
Configuration of
EXPO1 output
on input-output
1 EXPO
expansion board
Configuration of
EXPO2 output
on input-output
2 EXPO
expansion board
TRAFFIC LIGHT
Traffic light pre-fla-
PREFLASHING
TRAFFIC LIGHT
Steadily lit red light
RED LA P
ALWAYS
ON
TABLE "C" – RADIO MENU (RADIO)
Logic
Description
Add 1ch Key
add1ch
associates the desired key with the 1nd radio channel command.
Add 2ch Key
add2ch
associates the desired key with the 2nd radio channel command.
Add 3ch Key
add3ch
associates the desired key with the 3nd radio channel command.
Add 4ch Key
add4ch
associates the desired key with the 4nd radio channel command.
Erase List
erase 128
WARNING! Erases all memorized transmitters from the receiver's memory.
Eliminates individual radio control
Removes a radio control (if clone or replay is disabled) To select the radio control to be deleted, enter the position or press a button on the radio control to be deleted
erase 1
(the position is displayed)
INSTALLATION MANUAL
Cross out
Default
setting
used
0
1
2
3
4
5
6
0
7
1-3
8
9
10
11
12
0
1
11
2
3
4-5
4
5
6
7
8
9
10
11
11
6-7
12
13
14
15
16
0
0
shing
1
0
0
1
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing
the movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening
the movement stops.
Output configured as 2
Radio Channel.
nd
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light.
Output configured as Alarm.
Output configured as Flashing light.
Output configured as Latch.
Output configured as Magnetic lock.
Output configured as Maintenance.
Output configured as Flashing Light and Maintenance.
Output configured as Traffic Light control with TLB board.
Not used
Not used
Output configured as closed Gate Status
Output configured as Bistable Radio Channel
Output configured as timed Radio Channel
Output configured as open Gate Status
Red lights flash, for 3 seconds, at start of operation.
Red lights off when gate closed.
Red lights on when gate closed.
Optional extras
THALIA BT A80 / BT A160 -
55

Publicité

loading