Télécharger Imprimer la page

BFT THALIA BT A80 Instructions D'installation page 53

Masquer les pouces Voir aussi pour THALIA BT A80:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
Logic
Definition
Ice feature
ICE
Number of active
OT. ON
motors
installation
Installation
alternative
alternative
Configuration of
safety input SAFE 1.
1 SAFE
Configuration of
safety input SAFE 2.
2 SAFE
Configuration of
safety input SAFE 10.
10 SAFE
Only with an
Configuration of
e x p a n s i o n
safety input SAFE 11.
11 SAFE
c a r d .
I f
you do not
Configuration of
u s e
t h e
safety input SAFE 12.
12 SAFE
e x p a n s i o n
card, leave
the default
setting (15)
Configuration of
safety input SAFE 13.
13 SAFE
Configuration of
command input IC 1.
1 IC
Configuration of
command input IC 2.
2 IC
Configuration of
command input
10IC
Only with an
e x p a n s i o n
Configuration of
card
command input
11IC
Configuration of the
1st radio channel
1ch
command
Configuration of the
2nd radio channel
2ch
command
Configuration of the
3rd radio channel
3ch
command
Configuration of the
4th radio channel
4ch
command
Configuration of
1AUX
AUX 1 output. 20-21
Configuration of
AUX 2 output.
2AUX
INSTALLATION MANUAL
Cross out
Default
setting
used
0
0
1
1
2
2
0
1
2
3
0
4
5
6
7
0
1
0
2
72
3
4
5
6
7
6
74
8
9
10
15
77
11
15
12
78
15
13
79
14
15
80
15
0
1
0
2
61
3
4
4
62
5
2
IC 10.
64
6
3
IC 11.
65
0
0
1
2
3
9
4
5
6
2
7
8
9
10
11
5
12
0
6
1
2
0
3
26-27
The Amperostop safety trip threshold stays at the same set value.
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
WARNING!! Check that the impact force value measured at the foreseen points is lower than that indicated in
the EN 12453 standard. If in doubt, use auxiliary safety devices.
This feature is useful when dealing with installations running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and closing cycle.
Only motor 1 active (1 leaf ).
Both motors are activated (2 leaves).
See Fig.E0
See Fig.E1
See Fig.E2
See Fig.E3
See Fig.E4
See Fig.E5
See Fig.E6
See Fig.E7
Input configured as Phot (photocell).
Input configured as Phot test (tested photocell).
Input configured as Phot op (photocell active during opening only).
Input configured as Phot op test (tested photocell active during opening only).
Input configured as Phot cl (photocell active during closing only).
Input configured as Phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
Input configured as Bar 8k2. (Inactive on SAFE 11,13).
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the move-
ment stops.
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing,
the movement stops.
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the
movement stops. (Inactive on SAFE 11,13).
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the move-
ment stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening,
the movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the
movement stops. (Inactive onSAFE 11,13).
Input configured as deactivated.
To be used without the expansion card.
(Not active on Safe 1,2).
Input configured as Start E.
Input configured as Start I.
Input configured as Open.
Input configured as Close.
Input configured as Ped.
Input configured as Timer.
Input configured as Timer Pedestrian.
Radio control configured as START E.
Radio control configured as Start I.
Radio control configured as Open.
Radio control configured as Close
Radio control configured as Ped
Radio control configured as STOP
Radio control configured as AUX1 **
Not used
Radio control configured as AUX11 ** (only with an expansion card)
Radio control configured as AUX2 **
Radio control configured as EXPO1 **
Radio control configured as EXPO2 **
Control configured as COURTESY LIGHT
The command enables the light with bi-stable logic. At least one auxiliary output must be set as a courtesy
light
Output configured as a monostable radio channel
Output configured as SCA, gate open light.
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Optional extras
Excluding IGEA BT
Only for VIRGO
THALIA BT A80 / BT A160 -
53

Publicité

loading