Mod.
V
Code
A
kW
Hz
Serial N.
Ph
bar/psi
ensure that the voltage drop under full load does not
exceed 4% (10% during
start-up) of the rated voltage value specified on the plate
- The user must:
• fit a power plug in compliance with current regulations
on the power supply lead;
• connect the machine to its own electrical connection
- A, Fig. 2 - equipped with a differential automatic
circuit breaker with 30mA sensitivity;
• install protection fuses on the power line that are suitably sized in accordance with the indications
provided on the machine data plate (Fig.1);
• connect the machine to an industrial socket; the machine must not be connected to domestic
sockets.
Make sure that the available pressure and performance of the compressed air system are
compatible with what is necessary for correct machine operation - see
the section "Technical data". For the correct operation of the machine, the pneumatic
supply line must provide a pressure range from a minimum of 8 bar to a maximum of 16 bar.
For correct equipment operation, the air produced must be suitably treated (not
above 5/4/4 according to standard ISO 8573-1).
Check that the lubrication cup (B, Fig. 2a contains
lubricating oil; top up is necessary. Use SAE20 oil.
The pneumatic supply inlet point, in the workshop
line, must be equipped with a pneumatic supply
shut-off valve, placed upstream the filter/regulator
unit supplied with the machine (B Fig. 2a).
98
ISO9001
QUAL. SYS. CERTIFIED
ANNO DI COSTRUZIONE /
MANUFACTURED
X-XXXXXXXX/XX - XX
1
XXXXXXXXX
WARNING
Startline S 424-S 421-S 521-S 524 Operator manual
A
2
B
2a