WATER DRAIN CONNECTION
To perform this operation, do the following.
1. Connect the water supply line pipe (A) to the appliance's connection pipe (C).
2. Connect the vent pipe (D) to the appliance connection pipe (C) and attach it to the support (E).
The appliance's drain line is fi tted with the plug
(B) to allow discharge of the any waste.
ELECTRICAL CONNECTION
The appliance must be connected, grounded in
accordance with all local codes, or in the absence of
local codes, with the National Electrical Code, ANSI/
NFPA 70, or the Canadian Electrical Code, CSA C22.2.
IMPORTANT _________________________
The connection must be made by authorized,
skilled personnel, in accordance with the
relevant legal requirements, using appropriate
and specifi ed materials. The appliance is
supplied
with
operating
or 240V/3 (available on request only for
model FX61-101-82-122-201-202) or 480V/3
for FX202 (available on request only for model
FX101-82-122) (see wiring diagrams).
WARNING Before performing any service
that
involves
electrical
disconnection and/or exposure to electrical
components, always follow the Electrical
LOCKOUT/TAGOUT Procedure. Disconnect
all circuits. Failure to comply can cause
property damage, injury or death.
WARNING
Before doing any work, cut
off the main electricity supply.
C
A
voltage
208V/3
connection
or
D
C
B
Connect the appliance to the main power supply as
follows.
1. Remove the screws and side panel (A).
2. Connect power input wires to the appliance's
terminal board (C), in accordance with the electrical
system diagram provided at the back of the manual,
using a cable with the following characteristics.
• Wire insulation temperature rating: ≥75°C (167°F).
3. Replace side panel (A) and retighten all screws
when the operation is complete.
C
Combination Oven Installation and Operation Manual
Section 4
Handling and Installation
3.94 in
E
A
B
21