Télécharger Imprimer la page

Agilent Technologies Navigator TV 1001 Notice De Mode D'emploi page 271

Publicité

Window-Meanings
Tab. 8
N.
000
008
100
101
102
103
104
105
106
107
TV 1001 Navigator User Manual / 87-900-945-01(L)
RS 232/RS 485 Communication Description
Read/Write
Datatype
R/W
L
R/W
L
R/W
L
R/W
N
R/W
N
R/W
N
R/W
L
R/W
N
R/W
L
R/W
L
Technical Information
Description
Start/Stop
(in remote mode the window
is a read only)
Remote
(default) or Serial
configuration
Soft Start
(write only in Stop condition)
Set Point type
Set Point threshold (expressed
in Hz, mA or s)
Set Point delay: time
between the pump start and
the set point check (seconds)
Set Point signal activation type:
the signal can be "high level
active" or "low level active"
Set point hysteresis
(in % of threshold)
Intercooling
Active Stop
(write only in stop)
17
Admitted Values
Start = 1
Stop = 0
Remote = 1
Serial = 0
(default = 1)
YES = 1
NO = 0
0 = Frequency
1 = Current
2 = Time
(default = 0)
(default = 582)
0 to 99999
(default = 0)
0 = high level
active
1 = low level
active
(default = 0)
0 to 100
(default = 2)
0 = NO
1 = YES
0 = NO
1 = YES
271/310

Publicité

loading