Les langues disponibles

Relay output
External setpoint input
ASI interface
Protection against
short-circuits
Type of cable recommended
Electrical connection
NPN version
PNP version
NPN/PNP version
Relay version (with or without
External setpoint board)
Relay+AS-Interface version
Housing
Housing material
Front plate
Parts in contact
with the medium
Protection rating
Environment
Ambient temperature
Relative humidity
8400
All manuals and user guides at all-guides.com
Relay version: 250 VAC, 3 A max. or 30 VDC, 3 A max. ; programmable
Relay+AS-Interface or relay+External Setpoint versions:48 VAC, 3 A max. or 30 VDC,
3 A max.; programmable
4-20 mA (option)
field bus (option)
yes for the transistor output
shielded, wire section between 0.14 and 0.5 mm
DIN 43650 connector (supplied)*
DIN 43650 connector (supplied)*
M12 female connector, 5 pins (not supplied)
DIN 43650 connector (supplied)* and M12 female connector, 5 pins (not supplied)
DIN 43650 connector (supplied)* and M12 female connector, 2 pins (not supplied)
* EaseOn with 2511 connector on request
polycarbonate, fiber glass reinforced
polyester
stainless steel 316L (DIN 1.4404), FPM in the standard versions (EPDM as an option)
IP 65, connectors being plugged-in and tightened
0 to +60° C (+32° F to +140° F)
< 80%, non condensated
2