Télécharger Imprimer la page

Burkert 8400 Manuel D'instructions page 13

Masquer les pouces Voir aussi pour 8400:

Publicité

Les langues disponibles

Les langues disponibles

1
2
Multipin M12 connector (not supplied)
- Loosen threaded ring [1]
- Remove part [2] from the connector.
- Wire according to pin assignment (see 4.3.2)
8400
All manuals and user guides at all-guides.com
4.3 Electrical connection
Always ensure the power supply is switched off before working on the
device. All the connectors must be plugged out. Use:
- a shielded cable with an operating temperature > +80° C (+176° F).
- a high quality voltage supply (filtered and stable).
Install the following security devices:
- for the power supply: a 1-A fuse
- for the relay: a 3-A fuse and a circuit breaker (depending on
the application).
4.3.1 Connectors
DIN 43 650 connector (type 2508, supplied)
- Remove part [3] from part [2].
- Wire according to pin assignment (see 4.3.2 or 4.3.3)
- Replace part [3].
- Tighten the cable gland [5].
- Place gasket [4] between the DIN43650 connector and the
fixed connector of the 8400.
- Connect the DIN43650 connector to the 8400.
- Tighten screw [1].
13
2
1
3
5
4

Publicité

loading

Ce manuel est également adapté pour:

8400 extended