8.2. installing the Process Valve
Thread type and dimensions can be found in the corresponding data
sheet.
Connect the valve according to the operating instructions for the
valve.
8.3. Pneumatic connection of the control
head
Danger!
risk of injury from high pressure!
• Before dismounting pneumatic lines and valves, turn off the
pressure and vent the lines.
procedure:
Connect the control medium to the pilot air port (1)
(3 – 7 bar; instrument air, free of oil, water and dust).
Attach the exhaust airline or a silencer to the exhaust air port (3)
(see "Fig. 8: Pneumatic Connection").
Caution: (Exhaust air concept):
In compliance with protection class IP67, an exhaust air line
must be installed in the dry area.
Keep the adjacent supply pressure always at least 0.5 –
1 bar above the pressure which is required to move the
actuator to its end position.
All manuals and user guides at all-guides.com
Type 8695
Important information for the problem-free functioning of
the device:
• The installation must not cause back pressure to build up.
• Select a hose for the connection with an adequate
cross-section.
• The exhaust air line must be designed in such a way that
no water or other liquid can get into the device through
the exhaust air port.
Fig. 8:
Pneumatic Connection
english
Pilot air port
(label: 1)
Exhaust air port
(label: 3)
15