1 - DESCRIPTION OF THE APPLIANCE
1.1 - EXTERNAL UNIT (Fig.1)
For the characteristics of the external unit, please refer to the installation manual of the external unit.
1.2 - INTERNAL UNIT (Fig.2-4)
The dimensions of the internal unit are:
Width (mm)
Depth (mm) + control panel
Height (mm)
Weight - Weight in use (kg)
List of main components of the internal unit (Fig.4)
1.
Three-way valve
2.
Conditioning circuit circulation pump
3.
Safety valve (6 bar DHW circuit)
4.
Reheating electric heaters collector
5.
3 bar conditioning circuit safety valve
6.
Electric heaters safety thermostats
7.
Automatic air vent valve
8
Conditioning circuit heat exchanger
9.
Flow switches
10. Conditioning circuit manometer
11. DHW thermostatic mixer
12. DHW circuit circulation pump
13. DHW circuit heat exchangers
1.3 - LIST OF SUPPLIED COMPONENTS
The appliances are shipped with standard packaging composed of an enclosure and cardboard corners and
a series of expanded polystyrene guards. Under the packaging of the units is located a 750 x 750 mm pallet
which eases transport and displacement operations.
Inside the packaging, together with the internal unit, the following components are supplied:
• External air sensor kit
1.4 - RECEIPT AND UNPACKING
The packaging is made up from suitable material and performed by expert personnel.
The units are delivered complete and in perfect condition. However, for he quality control of the transport
services, follow the warnings below:
a. On receipt of the packages, check whether the packaging is damaged. If this is the case, withdraw the
goods with reserve, producing photographic proof and any apparent damage.
b. Unpack, checking the presence of the individual components with the packing lists.
c. Control that all components have not undergone damage during transport. If this is the case, inform the
carrier by registered letter with acknowledgement of receipt within 3 days of receiving the goods, presenting
photographic documentation.
d. Pay attention when unpacking and installing the equipment.
Sharp parts can cause injury. Pay particular attention to the edges of the structure and the fin of
the condenser and evaporator.
No information concerning damage undergone can be taken into consideration
after 3 days from delivery.
For any controversy the court of jurisdiction will be BRESCIA.
UI SHERPA AQUADUE TOWER S3 E
600
600
1980
171 - 321
14. DHW circuit expansion vessel
15. Domestic Hot Water (DHW) reservoir
16. Tester anode
17. Conditioning circuit expansion vessel
18. Touch screen display
19. Electric panel assembly
20. DHW circuit evaporator water flow adjuster
A.
Adjustable support feet
B.
DHW reservoir emptying tap
C.
Magnesium anode
D.
Tester anode verification button
E.
Cable terminal fixing nut + tester anode
SHERPA AQUADUE TOWER
EN - 13