IX - What to do if...? ... Check.
What to do if...?
- No synchronisation after
installation
- The NTP receiver is not
set to the correct time
- The unit needs to
be returned to factory
configuration
- There is no DHCP server
on the network
- One of the clocks Style
does not ignite or makes
restarts in loops.
- Check that the signal type sent by the master clock is the same
as the clock's signal type (IE NTP).
Checked that the IP address of the server is identical on the
clock's web interface and the receiver.
- The NTP server is on the same network as the receiver (IP ad-
dress, subnet mask and gateways).
- Check the time zone selected in the web interface.
- Shunt the rider in the back of the product during at least 3
seconds.
The network configuration used by default by the clock is as
follows:
- IP : 172.17.30.110
- MASK : 255.255.0.0
- GATEWAY : 0.0.0.0
- DNS : 0.0.0.0
1) The maximal power of the switch PoE is sufficient to feed all the
clocks connected to the switch.
2) The length of the cable is lower than 100 meters (refer to the
standards of network cabling).
3) All the exits of the switch are compatible PoE.
26
... Check