9.2.1 To replace the antistatic plastic bag
EN
1
Check that the risk area is clear.
2
Ensure that there is no vacuum in the dust separ-
ator.
3
Remove the collector bin.
4 Seal and remove the antistatic plastic bag. Use a
cable tie or equivalent, see Figure 12.
5
Fit a new antistatic plastic bag in the collector bin,
see Figure 13.
6
Refit the collector bin onto the dust separator.
7
Check that the pressure equalizer hose is attached
to the collector bin, see Figure 14.
8 Check that the collector bin seals properly once
the vacuum is re-applied to the dust separator.
9.3 Filter package
Fitting the steel ring correctly is important to
maintain the tightness and durability of the
unit.
Filter replacement is to be noted in the service pro-
tocol of the unit. Replacing individual filter bags is
possible, but it is recommended that the whole filter
package is replaced since it is quicker and causes less
spreading of dust.
The work is easy, if the unit is placed so it can be
tilted, see
Figure 15
straight up, see Figure 16, with a crane or other lifting
device.
If the filter bags are replaced separately, the plastic
holders will also have to be replaced.
Figure 17, items A–C, shows how the rubber sealing
rings are to be fitted. When a used sealing ring is to be
re-used, the form when open may differ from the ori-
ginal form as shown in item A.
Use a screwdriver to bring the edge of the module
between the rubber lips to obtain the result shown in
item C.
9.4 Change control filter
WARNING! Risk of personal injury
• The vacuum and compressed air to the unit
must be turned off before commencing filter
change.
• Use proper protective equipment.
Always check the main filter for damage when
replacing the control filter.
The control filter should normally be replaced after
6000 hours of operation. The control filter must also
36
All manuals and user guides at all-guides.com
FlexPAK 800/1000 DX
Also, the filter may be lifted
be replaced if damaged or if there is a high-pressure
drop over the control filter.
Follow the procedure below:
1
Access the filter by removing the lid and side of
the FlexPAK 800/1000 DX.
2
Disconnect the top piping of the filter housing and
open-top cover.
3
Remove and put the old filter in a large plastic bag,
or wrap in plastic foil. Avoid dust spreading.
4 Fit a new filter cartridge in place. Ensure that the
filter cartridge is centred and that the rubber seal
on the housing is intact.
5
Close the top cover and reconnect the pipes.
6
Check the earth connection between the control
filter and GND1.
10 Spare Parts
CAUTION! Risk of equipment damage
Use only Nederman original spare parts and ac-
cessories.
Contact your nearest authorized distributor or
Nederman for advice on technical service or
if you require help with spare parts. See also
www.nederman.com.
10.1 Ordering spare parts
When ordering spare parts always state the following:
• The part number and control number (see the
product identification plate).
• Detail number and name of the spare part (see
www.nederman.com/en/service/spare-part-
search).
• Quantity of the parts required.
11 Recycling
The product has been designed for component mater-
ials to be recycled. Different material types must be
handled according to relevant local regulations. Con-
tact the distributor or Nederman if uncertainties arise
when scrapping the product at the end of its service
life.
11.1 Environmental information
The following environmental information is valid for
FlexPAK 800/1000 DX:
• Cadmium-free and halogen-free relays in the control
equipment.
• Solvent-free washing and lacquer.
• 93.6% recyclable.