6.1.4 FlexPAK Idling (Idling mode)
The unit is in Idling mode. The pump motor is on, there is no vacuum, and the FCV is open. The unit goes into
Idling mode when there has been no pilot signal for the time set in DIR_Time.
FlexPak
Hi Vacuum Unit
IDLING
Time To StandBy
05:33m
6.1.5 Filter Cleaning
The unit is cleaning its main filter.
Filter
Cleanining
Cycles
Elapsed
Clean
00:00 s
Charge
00:00 s
6.2 Warning messages
If a warning is activated, there is a problem that needs to be corrected, but the unit continues to work. If a warn-
ing message is displayed in the PLC display, the light in the Standby/Running button flashes one second on, one
second off. This 1/1 on/off sequence continues until the problem is corrected. See also the PLC Settings Manual
and the Installation and Service Manual.
There are two exceptions to this rule, Section '3.2.1 Time For service' in the PLC Settings Manual and
tion 6.2.2 Bag Replacement Switch Activated
6.2.1 Dustbin Full
The Bin Level Indicator has detected that the dust bin has been full for 12 minutes.
• Empty the dust bin and press 'OK' to reset the warning.
Warning!
D u s t b i n F u l l
Th 15:01
Time To Unit
Stop 05:00 m
Reset OK Æ
All manuals and user guides at all-guides.com
FlexPAK 800/1000 DX
ESC
OK
1
0
ESC
OK
in this manual.
ESC
OK
TimeToStandby: The amount of time until the unit
goes into Standby mode. The default setting is 12
minutes.
Cycles: How many cleaning pulses will be carried out.
Elapsed: How many cleaning pulses are made.
Clean: Remaining time for cleaning pulse.
Charge: Remaining vacuum build time; the time until
cleaning pulse is activated.
Clean: Remaining time for cleaning pulse.
Charge: Remaining vacuum build time. The time un-
til the cleaning pulse is activated. Charge = Vacuum
building time (Charge time).
Pulse: How many cleaning pulses are made of 3.