TECHNICAL DATA
Model
Voltage
Power consumption
Max. pressure
Water consumption
Max. pressure water intake
Length hp hose
Water temperature
Automatic start-stop
Protection class
Protection level
Noise level
Dimensions
Weight
Technical changes reserved
IMPORTANT SAFETY REGULATIONS
1. Check your machine for visible damage before every use (incl.
cable, plug, hose and nozzle). Also check the connections for leaks.
Do not use a machine that is damaged or did not work perfectly on
the
previous
repairs/replacement.
2. The Voltage and frequency stated on the machine must correspond
with those of the socket to be used. The electrical installations must
be approved (IEC 60364-1) and secured with an earth leakage
switch (max. 30 mAmp.). Never alter the plug or socket in order to
make them fit! Faults in the electrical connection may cause electric
shocks!
3. If an extension cable is unavoidable, use a cable of sufficient
thickness: 1 mm² for cables to 12.5 metres, 1.5 mm² for cables to
20 metres and 2.5 mm² for cables to 30 metres in length. Unroll the
Force 1600
AC 220-240V, 50Hz
1600 Watt
13MPa (130 bar)
360 l/h
0,7MPa (7 bar)
5 meter
0-40°C
+
II
IPX5
77 dB(A)
26 x 21 x 80 cm.