Assembly
1. Insert valve seat (7) with the ball seat surface facing
up into the housing (8).
2. Insert O-ring (6) into the housing (8).
3. Insert filter cartridge (3).
4. Place thin seal (5) on threaded section of housing (8).
5. Place thick seal (4) on top of thin seal (5).
6. Slide pressure spring (2) onto housing cover pin (2).
7. Screw on housing cover (1) and tighten by hand.
8
HC 920 • HC 940 • HC 960
GB
8.4 Cleaning Airless spray gun
Intake filter in Airless spray gun
Dismounting (fig. 17)
1.
2.
1
3.
Mounting
1.
2
2.
3.
3
4
5
6
7
Cleaning the unit (shutting down)
Rinse Airless spray gun with an appropriate cleaning
agent.
Clean tip thoroughly with appropriate cleaning agent
so that no coating material residue remains.
Thoroughly clean the outside of the Airless spray
gun.
Pull protective guard (1) forward vigorously.
Screw handle (2) out of the gun housing. Remove
intake filter (3).
Intake filter congested or defective – replace.
Place intake filter (3) with the long cone into the gun
housing.
Screw handle (2) into the gun housing and tighten.
Snap in protective guard (1).