Safety regulations
b Installing the unit (gasoline units)
Use the Airless spraying unit with a gasoline
engine, preferably outdoors.
Take the wind direction into account. Then
place the unit so that no vapors containing
Danger
solvents are deposited in the area of the unit.
Observe a minimum distance of 3 m between the unit
with gasoline engine and the spray gun.
b Using unit on construction sites
(electric units)
Connection to the mains only through a special feed
point, e.g. through an error protection insallation with
INF < 30 mA
b Ventilation when spraying in rooms
Adequate ventilation must be guaranteed in order to re-
move the solvent vapors and the exhaust fumes of the
gasoline engine.
b Suctions installations
These are to be set-up by the user of the unit according
to local regulations.
b Earthing of the object
The object to be coated must be earthed.
b Cleaning the unit with solvents
When cleaning the unit with solvents, the sol-
vent should never be sprayed or pumped
back into a container with a small opening
(bunghole). An explosive gas/air mixture can
arise. The container must be earthed.
Danger
b Cleaning the unit
Danger of short-circuits caused by water
ingressing into the electrical equipment of
the gasoline engine.
Never spray down the unit with high-pres-
Danger
sure or high-pressure steam cleaners.
b Work or repairs on the electrical
equipment
Only have this work carried out by a qualified electrician.
No liability will be taken for incorrect installation.
b Working on electrical components
Remove the power cord from the socket during all repair
work.
HC 920 • HC 940 • HC 960
GB
b Setting-up on uneven surfaces
The front side of the unit must point downwards to pre-
vent sliding away.
2.
General view of application
2.1 Application
Priming and final coating of large areas, sealing, impreg-
nation, construction sanitation, façade protection and ren-
ovation, rust protection and building protection, roof coat-
ing, roof sealing, concrete sanitation, as well as heavy
corrosion protection.
Examples of objects to be sprayed
Large-scale construction sites, underground construction,
cooling towers, bridges, sewage treatment plants and ter-
races.
Generally for the whole building protection where opera-
tion without electric power is required.