English
9.5.3 Dismantling the Wilo-CronoNorm-
NLG
Slide-in unit
83
NOTE:
For installation work, please also observe the sectional drawings in
section 11.2 "Spare parts lists, Wilo-CronoNorm-NLG" on page 97.
Slide-in unit:
1.1
1.2
Fig. 24: Slide-in unit
See Fig. 24:
• Mark positions of the parts which belong together with a coloured
pen or scriber.
• Remove the hexagon head bolts (12) (connection of housing cover
(4.1) and spiral housing (1.1)).
• Pull the pull-out slide-in unit straight out of the spiral housing (1.1) to
avoid damage to interior parts.
• Put the slide-in unit down at a safe workplace.This assembly must be
removed vertically to avoid damage to the impellers, stationary wear
rings and other parts.
• Remove the O-ring (1.2).
7.1
7.2
Fig. 25: Slide-in unit
See Fig. 25:
• Remove the hexagon head bolts (7.2) and remove the protective
screen (7.1).
• Loosen the impeller nut (2.2).
• Remove the impeller (2.1) and key (3.2).
4.1
2.2
2.1
3.2
9
WILO SE 07/2013
12