2.7
Unauthorised modification and
manufacture of spare parts
2.8
Improper use
3
Transport and interim storage
3.1
Shipping
Transport inspection
Storage
Installation and operating instructions Wilo-CronoNorm-NL, NLG
Unauthorised modification and manufacture of spare parts will impair
the safety of the product/personnel and will make void the manufac-
turer's declarations regarding safety.
Modifications to the product are only permissible after consultation
with the manufacturer. Original spare parts and accessories author-
ised by the manufacturer ensure safety. The use of other parts will
absolve us of liability for consequential events.
The operating safety of the supplied product is only guaranteed for
conventional use in accordance with Section 4 of the operating
instructions. The limit values must on no account fall under or exceed
those specified in the catalogue/data sheet.
The pump is lashed to a pallet ex works and is protected against dirt
and moisture.
On arrival, inspect the pump immediately for any transport damage. If
damage is found, the necessary procedures involving the forwarding
agent must be taken within the specified period.
Before installation, the pump must be kept dry, frost-free and pro-
tected from mechanical damage.
NOTE:
Improper storage can lead to damage to the equipment, which is
excluded from the guarantee and warranty.
Short-term storage (less than three months):
If it is required to store a pump before its installation for a short time,
keep it in a dry, clean and ventilated place, which is free of vibrations,
moisture and fast/extreme temperature differences. Protect the
bearings and couplings from sand, gravel and other foreign objects.
To prevent rust and bearing seizing, lubricate the unit and turn the
rotor by hand by several rotations at least once a week.
Long-term storage (more than three months):
If it is planned to store the pump over a longer period of time, addi-
tional precautionary measures must be taken. All rotating parts must
be coated with a suitable protective medium to protect them from
rust.If the pump should be stored for more than a year, consult the
manufacturer.
CAUTION! Risk of damage due to incorrect packaging!
If the pump is transported again at a later time, it must be packaged
so that it cannot be damaged during transport.
• Use the original packaging for this, or choose equivalent packag-
ing.
English