Wilo-CronoNorm-NLG series
Fig. 4: Permissible forces and torques on
the pump flanges - Wilo-CronoNorm-NLG
series
DN
150
2050
200
3110
250
4450
300
5340
350
5780
400
6670
200
3780
250
5340
300
6670
350
7120
400
8450
450
9120
Installation and operating instructions Wilo-CronoNorm-NL, NLG
Z
Y
X
Z
Y
X
Forces F [N]
F
F
F
Y
Z
X
3110
2490
4890
3780
6670
5340
8000
6670
8900
7120
10230
8450
3110
4890
4450
6670
5340
8000
5780
8900
6670
10230
7220
10920
Tab. 4: Permissible forces and torques on the pump flanges - Wilo-CronoNorm-NLG series
Wilo-CronoNorm-NLG series (see Fig. 4 and Tab. 4)
Values in acc. with ISO/DIN 5199 - class II (1997) - Appendix B,
Family no. 2
• for installing on the cast frame without concrete casting and a
pumping temperature up to 110 °C, or
• for installing on the cast frame with concrete casting and a pumping
temperature up to 120 °C.
Forces F
M
Y
4480
1180
6919
1760
9634
2440
11705
2980
12779
3120
14851
3660
6919
1760
9634
2440
11705
2980
12779
3120
14851
3660
15955
4150
Torques M [Nm]
M
M
Torques M
Z
X
1760
2300
3127
2580
3560
4736
3800
5020
6752
4610
6100
8206
4750
6370
8537
5420
7320
9816
2580
3530
4713
3800
5020
6752
4610
6100
8206
4750
6370
8537
5420
7320
9816
5960
7720
10599
English
66