Maintenance
6.1
Update and data read-out
Do not connect external hard drives; the control unit does not work with external hard drives (max. 100 mA power supply).
Before use, the USB stick must have been formatted with FAT32 and assigned a name using a Windows PC. When a USB
flash drive is connected to the control unit, it will be recognised automatically. Then the data exchange menu will appear with
these selection options:
|0.1 Data read out|
|0.2 Software update|
|0.3 Read in parameters|
|0 System info|
If the
exchange
| menu.
Data exchange
Connect USB stick, |
Disconnect the control unit from the power supply, con-
Data exchange
nect the USB stick, the |
(Only possible if there is a corresponding file (*.hex) with the
correct file name on the USB stick).
|Data exchange|
Connect USB stick, the
appears. (Only possible if there is a corresponding file
(*.csv) with the correct file name on the USB stick).
Replace battery/ batteries
The control unit is equipped with batteries in case of a power
outage. These must be renewed when the corresponding
prompt appears in the display (error message
error|
).
NOTICE
Disconnect system from energy sources!
Ensure that the electrical components are dis-
connected from the electrical power supply dur-
ing the work.
Put the main switch (1) at the control unit into the OFF
position, and open up the housing.
Remove cable ties, unplug both batteries (2) and replace
with new ones.
Plug in new batteries and fix with cable ties.
010-700_07
menu is displayed, the ESC key can be used to select the previously described |
Data read-out
| menu appears.
Carrying out an update
| menu appears.
Read in parameters
menu
|Battery
Installation and operating instructions
Select |Data read-out|
with the system data is saved on the USB stick (*.csv).
Start up the control unit, select
the update is performed automatically. Follow the display
dialog.
Select |Read in parameters|
and confirm with OK; the parameters are read-in automati-
cally.
Data
and confirm with OK. A file
|Software update|;
, enter password