Serialnumber ..................... Serial number of the device
Typecode ........................... Type code of the device according to ISO 12176-2
Owner ................................ Owner of the device (see Section 7.5)
Software ............................ Software running
Total Log Counter .............. Number of all previously performed welding sequences performed
Maintenance Counter ......... Number of welding sequences performed since performing the last
Next Maintenance .............. Date of the next scheduled maintenance in the format dd.mm.yyyy
Logs on Flash .................... Number of logs which are currently to be found in the device's
Error entries ....................... Number of error entries
Error list
Error messages can be transferred onto a USB stick. These data can then (for example by
email) be sent to a ROTHENBERGER service engineer or an authorised partner. If the device is
defective or if the function of the device is impaired a remote diagnosis may possibly be made
on the basis of the error patterns.
8.1
Solution
Wrong password
A valid password has to be entered in order to navigate to the menu point Parameters or
Maintenance. Please inform yourself from the persons responsible for the device about your au-
thorisation level and the valid code.
Wrong Fitting
This error message appears if the fitting parameters taken from the fitting code do not match the
actually measured values. Please check whether the scanned in code matches the fitting.
Corrupt Fitting Code
The scanned in fitting code could not be decoded. Please check the code for damage or dirt.
No Fitting Detected
A welding sequence was attempted without a plugged in fitting. Please check the contacts of the
fitting and plug for damage or dirt.
Fitting Shortcircuit Detected
A short circuit was detected on the fitting. Please check the contacts of the fitting and plug for
damage or dirt.
Fitting diameter > 400 mm
The ROFUSE 400 Turbo can only weld fittings of up to 400 mm in diameter.
Dataloss at Start - Memory Full!!
If a welding sequence is started despite this message data loss will occur. The welding is NOT
documented. Back up all data using a USB stick and erase ALL logs.
An impermissible ambient temperature
The ambient temperature is outside the permissible range. Place the device in the shadow or
switch on the heater.
Undervoltage
Turn up the voltage during generator operation.
Overvoltage
Turn down the voltage during generator operation.
Frequency error
The frequency of the supply voltage is outside the permissible range.
for example: P24US2VAKDX
during the service life of the device
maintenance work
internal memory