Télécharger Imprimer la page

clage DEX 12 Next Instructions D'utilisation Et D'installation page 36

Masquer les pouces Voir aussi pour DEX 12 Next:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41
DEX 12 Next
6. Electrical connection
Wiring diagram
2
EN
1. Electronic circuitry
2. Heating element
3. Safety pressure cut-out
4. Connecting terminal
5. Safety thermal cut-out
All manuals and user guides at all-guides.com
Only by a specialist!
Please observe:
• e.g. VDE 0100
5
• The installation must comply with current IEC and national local regulations or any
1
particular regulations, specified by the local electricity supply company
3
• The rating plate and technical specifications
• The appliance must be earthed!
4
Structural prerequisites
• The appliance must be installed via a permanent connection. Heater must be
earthed!
• The electric wiring should not be injured. After mounting, the wiring must not be
direct accessible.
• An all-pole disconnecting device (e.g. via fuses) with a contact opening width of at
least 3 mm per pole should be provided at the installation end.
• To protect the appliance, a fuse element with trigger characteristic C must be fitted
with a tripping current commensurate with the nominal current of the appliance.