Combining Cabinets (Rif. 19) - Specialized Technician; Electrical Connection (Rif. 20) - Specialized Technician - Arneg Victoria FISH Manuel D'installation Et De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Victoria FISH
English

11.Combining cabinets (Rif. 19) - specialized technician -

To combine two or more cabinets in channel, proceed as follows:
Disassemble the shoulders (if present).
Position the cabinets side by side
Join the risers and the brackets, using the screws supplied
Make sure the alignment pins are inserted in their provided seats.
CHANNEL COMBINATION KIT
Pos.
1
Alignment pin Ø 4x80
2
Screw TCEI M8x50 (galvanized)
3
Screw TCEI M8x120 (galvanized)
4
Nut M8
5
Side sheet steel

12.Electrical connection (Rif. 20) - specialized technician -

BEFORE ANY OPERATION REMOVE VOLTAGE TO THE SYSTEM!
system must have a grounding connection!
The systems must be set up in accordance to the norms that regulate
manufacture, installation, use, and maintenance foreseen by the norms in
force in the country where the cabinet is installed.
ARNEG Spa rejects any responsibility toward the user and third parties for
damages caused by breakdowns or malfunctions of the systems arranged
upstream of the cabinet and for damages to the cabinet that stem from causes
directly ascribable to an electrical system malfunction.
The cabinet must be protected upstream with an automatic, omnipolar
magneto-thermal switch having adequate characteristics and which will serve
as the main line disconnecting switch.
It is the Client's responsibility to arrange the electrical power supply line up to the point
of connection to the cabinet. Sizing of the electrical power supply line must be
performed in accordance to the power absorbed by the cabinet (see Technical Data).
Remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
Consult the wiring diagrams before performing the connection.
Check that power supply voltage is the one reported on the rating plate.
Instruct the operator on the position of the switch so that it may be timely reached
in case of an EMERGENCY.
To ensure normal operation, the maximum variation of the voltage must range
between +/- 6% of the nominal value.
Check that the power supply line has wires with an appropriate diameter, that it is
protected against overcurrents, and that the leakages to ground are in compliance
to the norms in force.
The manufacturer or staff assigned by it is responsible for replacing a broken or
defective power cable.
If the electrical power supply is interrupted, check that all the electrical devices of
the store can restart without triggering the intervention of the overload protections;
if otherwise, modify the system so as to differentiate activation of the various
devices.
28
Position the glass panel correctly
Denomination
Pcs
Code
.
02941419 10
04711041
1
04711065
4
04230600 2
02334017 1