G - Electrical socket
14.Filling the unit - qualified operator -
To refill the unit, you must comply with some important rules:
the arrangement of goods, without leaving empty areas, guarantees optimum unit
function.
arrange the goods in a way that does not interfere with the circulation of the
refrigerated air (Rif. 14)
15.Defrosting and water discharge (Rif. 18)
The Dallas 3 line of refrigeration units is provided with a simple-stop defrosting
system by means of the stopping of the refrigeration cycle.
15_1.Water discharge:
To drain the defrost water, you need to:
have a floor drain with a slight incline
install the provided siphon between the unit drainage pipe and the floor connection.
hermetically seal the floor drainage area.
This will prevent unpleasant odours from forming within the unit, the dispersion of
refrigerated air and possible unit malfunctioning due to humidity.
Version with incorporated group:
The defrost water is collected in a specific drain and taken to a basin at the bottom of
the unit.
Periodically check that the hydraulic connections are still efficient, contacting a
qualified installer.
16.Anti-condensation and fog resistance
To prevent fogging due to condensation, low voltage electrical resistances are used on
the parts most subject to this, such as: front facing glass surfaces, frames and corners,
side facing glass surfaces, etc.
17.Lighting
Internal lighting of the unit is obtained through fluorescent lights.
For greater energy savings, the cabinet can be ordered complete with low
consumption LED lighting. This allows for:
reduced lighting consumption
reduced refrigerator load
lifespan of lights: over 6 years
uniform light intensity and colour
improved lighting as temperature decreases.
18.Bulb replacement (Rif. 17) - specialised technician -
Replace the bulbs as follows:
Turn off the unit's power supply.
Remove the methacrylate guard (1).
Rotate the bulb by approximately 90° (until it clicks) and remove it (2).
Insert the new bulb.
Reattach the methacrylate guard.
Restore the electricity supply.
If necessary, it is possible to replace the entire light fixture (3), by pressing
downward, with moderate force, to release the light fixture from the steel spring A.
19.Maintenance and cleaning - qualified operator -
BEFORE CARRYING OUT ANY MAINTENANCE WORK OR
CLEANING, FIRST DISCONNECT THE UNIT FROM THE VOLTAGE
SUPPLY BY MEANS OF THE GENERAL SWITCH. ALWAYS WEAR
PROTECTIVE GLOVES FOR CLEANING.