Lisbona 2
English
13. How to join the cabinets (Fig.27)
Step
1
Disassemble the shoulders (if present).
2
Positi on the cabinets side by side
3
Make sure the alignment pins 3-4-6 and the trough coupling 5 are inserted into their respec-
ti ve housings.
Att ach the uprights with hook (Fig.28). Insert the Allen wrench supplied with the channel
5
union kit into the hole made on the back panels.
4
Join the risers and the brackets A, using the screws supplied 1-2
Pos. Name
1
Screw TCEI M8x120
2
Nut M8
3
Alignment pin 4x80
4
Alignment pin 10x60
5
Trough coupling
6
Hook alignment pin
14. Electric connecti on
DANGER! Live parts. Electrocuti on.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
ensure that the casing does not come into contact with the electrical panel
Provide a suitable grounding system!
i
The systems must be set up in accordance to the norms that regulate manufacture, installa-
ti on, use, and maintenance foreseen by the norms in force in the country where the refrigera-
ti on system is installed.
To ensure normal operati on, the maximum variati on of the voltage must range between +/-
6% of the nominal value.
Liability
Power
power supply
44
Code
04711065
04230600
02940652
02047000
01334013
02040256
Customer
provide a power line to the cabinet connecti on point.
Installer
provide the anchoring devices for all the wires in input and out-
put to/from the cabinet.
ARNEG
ARNEG S.p.A. denies all liability with respect to the user or third
parti es for:
- damages caused by failures or malfuncti on of the systems
installed upstream of the cabinet
- damages to the cabinet due to causes arising directly from
malfuncti on of the electrical system
• the supply lines of the electric energy should meet the requirements of power
consumpti on of the cabinet chap.9.
• check that the power line:
- has wires with suitable cross secti on
- is protected against over-current, overload and dispersions toward earth in
accordance with the rules in force
Acti on
05060167 00 09-08-2016