EMC Information

Guidance and Manufacturer's Declaration – Electromagnetic Emissions
This device is intended for use in the electromagnetic environment specied below The user of this device should assure that it
is used in such an environment
Emissions Test
RF Emissions
CISPR 11
RF Emissions
CISPR 11
Harmonic Emissions
IEC 61000-3-2
Voltage Fluctuations/Flicker Emissions
IEC 61000-3-3
Emission of Radio Frequency Energy
RTCA/DO-160G Section 21
Guidance and Manufacturer's Declaration – Electromagnetic Immunity
This device is intended for use in the electromagnetic environment specied below The user of this device should assure that it
is used in such an environment
Immunity Test
IEC 60601 Test Level
Electrostatic
±8 kV contact
Discharge (ESD)
±2 kV, ±4 kV, ±8 kV, &
IEC 61000-4-2
±15 kV Air
Electrical Fast
±2 kV for Power Supply
Transient/Burst
Lines
IEC 61000-4-4
±1 kV for Input/Output
Lines
Surge
±1 kV Line to Line
IEC 61000-4-5
±2 kV Line to Ground
Voltage Dips, Short
0% U
05 cycle,
T
Interruptions and
45 deg inc
Voltage Variations on
Power Supply Input
0% U
1 cycle
T
Lines
IEC 61000-4-11
70% U
25 Cycles
T
(30 cycles if US)
0% U
5 sec
T
Power Frequency
30 A/m
(50/60 Hz) Magnetic
Field
IEC 61000-4-8
Note: U
is the AC mains voltage prior to application of the test level
T
46
Compliance
Electromagnetic Environment - Guidance
Group 1
The Device uses RF energy only for its internal
function Therefore, its RF emissions are very
low and are not likely to cause any interference
in nearby electronic equipment
Class B
The Device is suitable for use in all
establishments, including domestic
establishments and those directly connected to
Class A
the public low-voltage power supply network
that supplies buildings used for domestic
purposes
Complies
Category M
The Device is suitable for use onboard
commercial airplanes inside passenger cabin
Compliance Level
Electromagnetic Environment - Guidance
±8 kV contact
Floors should be wood, concrete or ceramic tile
If oors are covered with synthetic material, the
±2 kV, ±4 kV, ±8 kV, &
±15 kV Air
relative humidity should be at least 30%
±2 kV for Power Supply
Mains power quality should be that of a typical
Lines
home or hospital environment
NA- Device does not have
user I/O lines that are
longer than 3m in length
±1 kV Line to Line
Mains power quality should be that of a typical
NA- The device is a Class
home or hospital environment
II device and does not
connect to earth ground
0% U
05 cycle,
Mains power quality should be that of a typical
T
45 deg inc
home or hospital environment If the user of the
Device required continued operation during
0% U
1 cycle
power mains interruptions, it is recommended
T
that the Device be powered from an
70% U
25 Cycles
uninterruptible power supply or battery
T
(30 cycles if US)
0% U
5 sec
T
Power frequency magnetic elds should be at
30 A/m
levels characteristic of a typical location in a
typical home or hospital environment