Place the device on a vertical and solid
surface. Use a spirit level when placing the
device (Figure 8, pos. 1).
2.
Place the device with a minimum distance
(Figure 8) of:
150 cm from the ceiling;
30 cm from the side walls;
10 cm from the floor;
50 cm clearance on the front side.
3.
Do not mount the device:
immediately below a socket outlet;
on a ceiling or roof.
4.
Drill four holes for the brackets, the two
lower holes at least 125 mm above the floor.
The distance between the vertical holes
(Figure 9, pos. B) is 105 mm.
The distance between the horizontal holes is
approximately (Figure 9, pos. A and B)*:
Alutherm Baseboard 1000: 365 mm;
Alutherm Baseboard 1500: 455 mm;
Alutherm Baseboard 2000: 535 mm.
5.
Place wall plugs (Figure 9, pos. 2).
6.
Screw and tighten a left and a right bracket
(Figure 9, pos. 3) to the wall with a large
screw (Figure 9, pos. 4) using a Phillips
screwdriver (Figure 9, pos. 1).
28