Annexe
Fig. 82
Émetteurs/récepteurs FLSE-XT (explication)
1
2
3
4
5
6
7
8
9
10 Tropicalizing electronic boards
11 Ultrasonic transducer
12 Transducer and tube material
FLOWSIC100 Flare-XT Transmitter · Manuel d'utilisation · 8028060/1FPZ/V 1-1/2022-05 · © SICK Engineering GmbH
Ultrasonic sensor
F1F
FLSE100-XT
Meter layout
R
R90
H
Cross-duct H
M
Cross-duct M
S
Cross-duct S
P
Probe
Installation length
S
Standard
E
Extended
2
R90-24
4
R90-48
7
R90-72
Ex approval
A
ATEX/IECEx
C
CSA (NEC/CEC),FM (NEC)
I
INMETRO
Ex classification / temperature class
II 1/2 G Ex db [ia Ga] IIA T4 Ga/Gb
DA
Cl I, Div1, Grp.D, T4
II 1/2 G Ex db [ia Ga] IIB T4 Ga/Gb
DB
Cl I, Div1, Grps.CD, T4
II 1/2 G Ex db [ia Ga] IIC T6 Ga/Gb
DC
Cl I, Div1, Grps.BCD, T4
II 2 G Ex db IIC T6 Gb
DD
Cl I, Div1, Grps.BCD, T4
IC
II 1 G Ex ia IIC T6 Ga
Sensor electronics
Y
Yes
N
No
Material electronics housing
A
Aluminium
B
Stainless steel
Painting electronics housing
1
SICK standard painting
2
SICK offshore painting
Cable entries
A
Metric
B
NPT
C
Connector
1
Tropicalized - SICK standard
N
No
4I
42 kHz intrinsically safe
4D
42 kHz flameproof
1I
135 kHz intrinsically safe
A
Titanium
La valeur «X» dans le codage indique une version spécifique à un client.
13 Sensor contour material
2
Stainless steel
6
PTFE
14 Sensor retraction
R
Retractable
15 Sensor process connection
A
ASME B16.5, CL150 2" RF
B
ASME B16.5, Cl150 3" RF
C
ASME B16.5, CL300 2" RF
D
ASME B16.5, CL300 3" RF
E
EN 1092-1, PN25 DN50 RF
16 Sensor process connection execution
S
Seamless retraction flange
W
Welded retraction flange
17 Material process connection S/R unit
B
Stainless steel
18 Gas temperature range
E
-70 ... +280°C
F
-196 ... +280°C
19 Ambient tempurature range
A
-40...+70°C
B
-50...+70°C
C
-40...+55°C T6, -40...+70°C T4
D
-50...+55°C T6, -50...+70°C T4
20 PMI Test
P
PMI Test
N
No
21 HVROC Test
H
HVROC Test
N
No
22 Tag plate
A
Tag plate sticker
B
Tag plate stainless steel + sticker
N
No
23 Reserve
N
-
24
Reserve
N
-
25
Special solution
N
No
X
Special Solution
E
EXRE Upgrade