Eurofred 3CSA0013 Mode D'emploi page 54

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PRESS THE ' esc ' KEY TO QUIT THE MAXIMUM
TEMPERATURE DISPLAY MODE.
Antifrost Activation
The ' AFR U2 ' parameter (anti-frost) enables or disables the
antifrost function. The management of the antifrost data is
performed through the user parameters.
PRESS THE '  ' KEY;
THE DISPLAY SHOWS 'AFR' FLASHING.
USING THE '  ' OR '  ' ARROWS IT IS POSSIBLE TO
ENABLE OR DISABLE THE ANTIFROST:
0: DISABLED
1: ENABLED (THE DISPLAY SHOWS )
PRESS THE '  ' KEY TO CONFIRM THE
PROGRAMMING OR PRESS THE ' esc ' KEY TO QUIT
USER PARAMETERS.
Automatic Boiler Control by means of Collectors (ABC)
The function ' ABC U3 ' is an interesting addition to the
Manual mode.
When the function ' ABC ' is enabled, the collector pump, in
contrast to the Manual mode, in which it is always running,
is stopped if the collector temperature, measured by the
probe S1, drops below the temperature set in the ' TABC '
parameter in the installer parameters.
PRESS THE '  ' KEY;
THE DISPLAY SHOWS ' ABC ' FLASHING.
USING THE '  ' OR '  ' ARROWS IT IS POSSIBLE TO
ENABLE OR DISABLE THE ABC:
0: DISABLED
1: ENABLED (THE DISPLAY SHOWS  and
PRESS THE '  ' KEY TO CONFIRM THE
PROGRAMMING OR PRESS THE ' esc ' KEY TO QUIT
USER PARAMETERS.
54
)

Publicité

Table des Matières
loading

Produits Connexes pour Eurofred 3CSA0013

Table des Matières