multiples of 3, can be set using the single ' TMR ' parameter
present. The activation of the test is signalled on the display
with the ' TIMER ' icon.
AFTER SELECTING PARAMETER P7 PRESS
THE '  ' KEY.
THE DISPLAY SHOWS ' TMR ' AND THE NUMBER OF
CYCLES IN THE TEST.
PRESS '  '. THE DISPLAY
SHOWS 'TMR' FLASHING.
USING THE KEYS '  ' OR '  ' SET THE NUMBER OF
CYCLES TO 3, 6, 9, 12 OR 15.
PRESS '  ' TO CONFIRM THE PROGRAMMED DATA
AND START THE TEST. BY PRESSING ' esc ' THE
MODIFICATIONS ARE CANCELED AND THE DISPLAY
AGAIN SHOWS THE NUMBER OF PRESET CYCLES.
P8: MINIMUM TEMPERATURE LIMITATION
The parameter 'Minimum Temperature Limitation' on
collector is used to manage the Minimum Temperature
Thermostat used for activation of the collector pumps.
This thermostat stops the pumps operation whenever on the
relevant panel is measured a temperature lower than the one
set in this parameter.
The function 'Minimum Temperature Limitation' is not active
when in Manual operation mode, in ABC operation or in
case the pumps activation is caused by the intervention of
Recooling or similar functions.
AFTER SELECTING PARAMETER P8 PRESS
THE '  ' KEY.
WITH ARROWS '  ' OR '  ', YOU CAN CYCLE AMONG
THE FOLLWOWING THERMAL DATA FOR REGULATION:
- Setting of the collector minimum temperature ' MTC '
- Enabling/Disabling of the minimum
temperature limitation
51
' MTEN '