The parameters influencing the regulation of the selected
setup are listed in the annex ' DIAGRAM ' and can be
modified through the second installer parameter (P2).
Note: When going into parameter P1, the controller
will reset the maximum temperatures (MT) detected
until that moment. Furthermore, when quitting this
parameter, the controller will set again the temperature
display on the sensor S_1.
P2: SETTING THE THERMAL DATA
Using this parameter it is possible to set the thermal data
related to the selected installation:
Note: The control unit is supplied with pre-programmed
thermal data for optimal operation. Any change
to these values must be performed by qualified
personnel only. When changing the hydraulic
scheme by means of the parameter P1, the
thermal values (TS, TM, TAH and TABC) already
set will be reset at the default values.
AFTER SELECTING PARAMETER P2 PRESS
THE '  ' KEY.
USING THE  ' OR '  ' ARROWS IT IS POSSIBLE TO
SCROLL CYCLICALLY THROUGH THE THERMAL DATA:
- Safety temperatures
- Differentials
- Hysteresis of the differentials
- Hysteresis of the safety thermostats
- Hysteresis of the thermostats
- Offset
- Maximum temperatures
- Integration temperature
- ABC (Automatic Boiler Control) temperature
PRESS THE '  ' TO MODIFY THE THERMAL DATA
SELECTED; THE DATA WILL START FLASHING.
SET THE DESIRED NUMERIC VALUE USING
THE '  ' OR '  ' ARROWS.
PRESS THE '  ' KEY TO CONFIRM THE
PROGRAMMED SETTINGS OR PRESS THE ' esc ' KEY
TO CANCEL THE CHANGES.